Electric Fencing in Dry Conditions

Dry Vegetation

There is a misconception that dry vegetation touching an electric fence can cause fires – this is extremely unlikely, if not impossible. In order to create a short, vegetation needs to be damp or green so therefore the vegetation will not ignite. Once vegetation dries out it becomes non-conductive meaning any short created disappears. The only conceivable but still very unlikely scenario where an electric fence could start a fire is when a wire shorts to an earthed metal object, such as a steel post where insulators have broken, in the presence of abundant dry vegetation. This scenario is very unlikely to occur in practice, and even more so on a well-maintained fence. Farmers with fences on steel posts in particular therefore are advised to check these fences and ensure the livewires are well insulated.

Earthing

In dry conditions, the earth system attached to your Energizer will become less effective. Typically, dry conditions lead to higher fence voltages, low fence load (as vegetation is non-conductive when dry) and fences that do not create as good a shock as normal (depending on the quality of the earth system). If your electric fences are not controlling stock effectively in dry conditions, solutions such as Gallagher Super Earth Kits are available to improve your earth system. Gallagher i Series Fence Energizers also have an adjustable output target voltage, so can be turned down in dry conditions to reduce higher fence voltages. We also recommend a return earth fence design for all permanent fences in Australia.

Induction

Induction is another problem that occurs in dry weather. A common scenario is getting a shock off a steel gate or a non-live wire in an electric fence. This happens when current flows down a wire alongside an adjacent, effectively insulated wire not directly coupled to the electric fence. A voltage is then induced in the adjacent wire. This is more likely in dry conditions because the posts the non-live wire is connected to become insulators when dry. The solution to this problem is to earth the offending wire or gate by pushing a wire into the ground and stapling this across the non-live wires at the strainer post. Induction is not considered a fire risk whatsoever. Vegetation conductive enough to cause a short will effectively earth the non-live wire and prevent induction from occurring.

If your electric fence is not working as well as it should, or you would like further explanation of the above, please contact your local Territory Manager or Tech Support team on 1800 425 524

News and Events

Discover the latest in new products, Gallagher sponsored events and field days in your community.

Learn More

Newsletter

Interested in having offers, promotions & seasonal tips delivered straight to your inbox? Keep up to date by signing up to our monthly newsletter.

Subscribe

Register a Product

By taking just a few minutes to register your product, you will be instantly set up with our support team and have the option to receive notifications when new software and upgrades are available.

Register a Product

Gallagher Australia Pty Ltd 65 Scanlon Drive, Epping, VIC 3076, Australia
Freephone: 1800 425 524   Phone: +61 3 9308 7722

© Gallagher Group Limited 2017. All rights reserved.